Skip to main content

Bundle v2.1.2 (21.04.26)

Update notes

Written by Ervin Kubits
Updated yesterday

Gateway v2.1.1 (21.04.26)

  • Fixed possible lockout situation during Wi-Fi reconnect

  • Added commercial charger functionality

  • During first power up, BT pairing disabled after 1h. Keeps disabled even after normal power cycle

  • Re-enable BT pairing any time with special power cycling (3 consecutive power cycles, each less than 10s)

  • Now scans all visible Wi-Fi APs and connects to the one with best RSSI. This improves connectivity in multi AP networks(with same SSID)

  • Delays for Wifi and OCPP connection parameter updates. Allows extra time to also change Wi-Fi password before connecting to new AP in case of updated SSID

  • Added local network health-check on Wi-Fi

  • Improved internal logs

  • Many internal improvements and fixes



MCU v3.0.2 (19.04.26)

  • Fixed possible current limiting issue in case 6.0 A external limit was set

  • Added commercial charger related functionality (external MID meter, display and locking socket support)

  • Improved resuming from suspendedEV state

  • Fix possible false autostarts

  • Improved CP signal processing for increased stability and noise immunity

  • Fixed LMC comm alarm potentially not being set after boot

  • EV phase detection improvements

  • Added new status codes

  • Fixes in phase input parameters mapping

  • Improved internal logging and diagnostics

  • Improved testing features

  • Improved power loss handling

  • Other fixes and improvements



Front panel v1.7.0 (3.01.25)

  • Same as before