Features
User identification | RFID, VOOL APP |
Dynamic load management | DLM (2) and DPM (2) Below |
DLM response time | 50ms |
Compatible EVSE protocols | OCPP 1.6, OCPP 2.0 |
Energy metering | Integrated |
Firmware updates | OTA, USB, CAN |
External Interfaces
Internet connectivity | Wi-Fi (IEEE 802.11 b/g/n), Ethernet 10/100 |
External Modbus meter | RS485 |
Local device network | CAN |
Safety
Residual Current Detection | 6mA DC / 30mA AC |
Overvoltage category | CAT III |
Compliance | LVD, RoHS |
Protection against electric shock | CLASS I |
Extra safety features | Welded contact detection, power-on self-test, thermal throttling |
General Specifications
Dimensions (WxHxD) | 196 x 329 x 110 (WxHxD) |
Weight | 4 kg |
Mounting options | Concrete, wood, metal post |
Front panel | Prebuilt and interchangeable |
Operating temperature | -25…+65 C |
Ambient temperature range | -40…+50 C |
Enclosure environmental rating | Outdoor / IP55 |
Standards | EMCD 2014/30/EU, IEC 61851-1:2017, |
Standard warranty | 36 months |
Operating voltage | 90-265 VAC |
AC frequency | 50Hz or 60Hz |
Charging options | 1 Phase, 2 Phase(1), 3 Phase |
Current per socket | 6A-32A |
Cover panel | Wood, metal, plastic and others |
Power per socket | 1.3–22kW |
Output cable | 6.5m cable with a Type 2 plug |