Skip to main content
Technical data - LMC
Lauri Laineste avatar
Written by Lauri Laineste
Updated over a week ago

FEATURES

Gateway functionality

OCPP 1.6, OCPP 2.0

Energy metering

On-line and off-line energy metering and tracking

Integration

PV panels, batteries

Smart price monitoring

EU markets

Station master

64 chargers + other smart appliances

Dynamic load management

DLM (1) and DPM (1)

DLM response time

Below 50ms

Firmware updates

OTA

In combination with Charger and/or Multiphaser, LMC enables dynamic load management and dynamic phase management for 100% grid utilization.


EXTERNAL INTERFACES

Internet connectivity

4G, Wi-Fi (IEEE 802.11 b/g/n), Ethernet 10/100

External modbus meter

RS485

Local device network

CAN

Current input

3x external current transformer


SAFETY

Overvoltage category

CAT III

Compliance

LVD, RoHS

Protection against electric shock

CLASS I


GENERAL SPECIFICATIONS

Operating voltage

90-265 VAC

AC frequency

50 or 60Hz

Dimensions (WxHxD)

85 x 85 x 59 mm

Weight

0.3 kg

Mounting options

DIN-rail, bolt mounted

Operating temperature

-25...+65 C

Ambient temperature range

-40...+55 C

Cooling

Natural convection

Enclosure environmental rating

Indoor / IP22

Standards

LVD 2014/35/EU, EMCD 2014/30/EU

Standard warranty

36 months

Did this answer your question?