Skip to main content

Technical data - LMC

Written by Vool Support

FEATURES

Gateway functionality

OCPP 1.6, OCPP 2.0

Energy metering

On-line and off-line energy metering and tracking

Integration

PV panels, batteries

Smart price monitoring

EU markets

Station master

64 chargers + other smart appliances

Dynamic load management

DLM (1) and DPM (1)

DLM response time

Below 50ms

Firmware updates

OTA

In combination with Charger and/or Multiphaser, LMC enables dynamic load management and dynamic phase management for 100% grid utilization.


EXTERNAL INTERFACES

Internet connectivity

4G, Wi-Fi (IEEE 802.11 b/g/n), Ethernet 10/100

External modbus meter

RS485(currently only supporting Siemens PAC3220, but other Modbus compliant models may work)

Local device network

CAN

Current input

3x external current transformer


SAFETY

Overvoltage category

CAT III

Compliance

LVD, RoHS

Protection against electric shock

CLASS I


GENERAL SPECIFICATIONS

Operating voltage

90-265 VAC

AC frequency

50 or 60Hz

Dimensions (WxHxD)

85 x 85 x 59 mm

Weight

0.3 kg

Mounting options

DIN-rail, bolt mounted

Operating temperature

-25...+65 C

Ambient temperature range

-40...+55 C

Cooling

Natural convection

Enclosure environmental rating

Indoor / IP22

Standards

LVD 2014/35/EU, EMCD 2014/30/EU

Standard warranty

36 months

Did this answer your question?